[1]张俊忠△ 李振阳 张鹏 黎立 王世立.定量外固定器刚度对骨折愈合影响的组织学研究[J].中国中医骨伤科杂志,2018,26(01):5-9.
 ZHANG Junzhong LI Zhenyang ZHANG Peng LI Li WANG Shili.Histological Study of the Effect of Quantitative External Fixator Stiffness on Fracture Healing[J].Chinese Journal of Traditional Medical Traumatology & Orthopedics,2018,26(01):5-9.
点击复制

定量外固定器刚度对骨折愈合影响的组织学研究()
分享到:

《中国中医骨伤科杂志》[ISSN:1005-0205/CN:42-1340/R]

卷:
第26卷
期数:
2018年01期
页码:
5-9
栏目:
实验研究
出版日期:
2018-01-15

文章信息/Info

Title:
Histological Study of the Effect of Quantitative External Fixator Stiffness on Fracture Healing
文章编号:
1005-0205(2018)01-0005-05
作者:
张俊忠1△ 李振阳1 张鹏2 黎立2 王世立3
1山东中医药大学(济南,250014) 2山东中医药大学附属医院 3山东省医学科学院 通信作者 E-mail:13793188178@163.com
Author(s):
ZHANG Junzhong1△ LI Zhenyang1 ZHANG Peng2 LI Li2 WANG Shili3
1Shandong University of TCM,Jinan 250014,China; 2The Hospital Affiliated to Shandong University of TCM,Jinan 250014,China; 3Shandong Academy of Medical Sciences,Jinan 250014,China.
关键词:
骨折 外固定器 刚度 组织学 实验研究
Keywords:
Keywords: fracture external fixator stiffness histology experimental research
分类号:
R-33
文献标志码:
A
摘要:
目的:探讨不同刚度外固定对骨折愈合的影响。方法:18只健康雄性SD大鼠随机分为低刚度组和高刚度组,均行股骨干中段横行截骨,分别以自行设计的18.5 N/mm(低刚度组)和60.6 N/mm(高刚度组)刚度的外固定支架固定。术后6周一次性处死大鼠,对骨折愈合情况进行组织学观察。结果:高刚度组骨折愈合,新生骨痂连接骨折断端,骨痂中可见大量活跃的骨细胞; 低刚度组大鼠股骨干均表现肥大性骨不连。1)在股骨干增粗处均是新生骨,骨细胞较多且活跃,表现膜内成骨; 2)骨折端软骨内成骨为主; 3)软骨成骨活跃,形成了明显的肥大区和成骨区,在与正常骨组织接触处形成了软骨成骨的骨痂组织。结论:肢体负荷与固定器刚度是调节骨折端稳定性的两个重要因素,稳定性决定着骨折愈合的形式和性质。因此,在固定器刚度不变的情况下,可以通过控制肢体负荷来调节骨折端的稳定性,从而调节骨折愈合过程。
Abstract:
Abstract Objective:To explore the effect of different external fixation stiffness on fracture healing.Methods:All 18 healthy male SD rats were randomly divided into low stiffness and high stiffness group.Two groups were performed the middle femoral bone cutting.And they were fixed by different support of the self-designed 18.5 N/mm(low stiffness group)and 60.6 N/mm(high stiffness group)stiffness of external fixations respectively.Six weeks after the operation all rats were killed at once.To observe the histology of the fracture healing.Results:In the high stiffness group,new bone scabs link of fracture broken end,and bone scabs were visible in a large number of active bone cells,with the fracture healing.In the low stiffness group,the femoral shaft of rats were characterized by hypertrophic nonunion:1)In the femoral enlargement were new bone,bone cells were more and active,and they were showed intramembranous ossification; 2)Fracture end was given priority to endochondral ossification; 3)The osteogenesis of cartilage was active,hypertrophy and ossification were formed obviously.The bone scab formed from the cartilage in contact with normal bone tissue.Conclusion:The physical load and stiffness of the fixator are two important factors which can regulate the stability of fracture end.Stability decided the modality and nature of fracture healing.Therefore,in the case of the same stiffness,we can regulate the stability of fracture site by controlling the body load,and we can regulate the process of fracture healing eventually.

参考文献/References:

[1] 李颖,黎立,李俊玲,等.力学环境对骨折早期骨折端间充质干细胞募集的影响[J].国际骨科学杂志,2016,37(3):198-202.
[2] Liu M,Liu N,Zang R,et al.Engineering stem cell nichesinbioreactors[J].World J Sten Cells,2013,5(4):124-135.
[3] Hasenboehler E,Rikli D,Babst R.Locking compression plate withminimally invasive plate osteosynthesis in disphyseal and distal tipialfracture:a retrospective study of 32 patients[J].Injury,2007,38(3):365-370.
[4] Gardner MJ,van der Meulen MC,Demetrakopoulos D,et al.In vivo cyclic axial compression affects bone healing in the mouse tibia[J].Journal of Orthopaedic Research,2006,24(8):1679-1686.
[5] Castillo AB,Jacobs CR.Mesenchymal stem cell mechanobiology[J].CurrOsteoporos Rep,2010,8(2):98.
[6] Kelly D,Jacobs CR.The role of mechanical signals in regulatingchondrogenesis and osteogenesis of mesenchymal stem cell[J].Birth Defects Res,2010,90(1):75-85.
[7] Gupta RR,Kim H,Chan YK,et al.Axial strain enhances osteotomyrepair with a concomitant increase in connexin43 expression[J].Bone Res,2015,3(2):83-91
[8] 宋文超,段宜强,尹培荣,等.可控性应力与微动对骨折愈合影响的组织学研究[J].中华创伤骨科杂志,2010,12(3):256-259.
[9] Hente R,Füchtmeier B,Schlegel U,et al.The influence of cyclic compression and distraction on the healing of experimental tibial fractures[J].Journal of Orthopaedic Research,2004,22(4):709-715.
[10] Augat P,Burger J,Schorlemmer S,et al.Shear movement at the fracture site delays healing in a diaphyseal fracture model[J].Journal of Orthopaedic Research,2003,21(6):1011-1017.
[11] Yuan L,Sakamoto N,Song G,et al.High-level shear stress stimulates endothelial differentiation and VEGF secretion by human mesenchymal stem cells[J].Celluar & Molecular Bioengineering,2013,6(2):220-229.
[12] 宋文超,张思森,陈勇,等. 可控性应力与微动对骨折愈合影响的CT 影像结果[J].中华创伤骨科杂志,2015,17(7):624-628.
[13] Andrew J.Steward,Daniel J.Kelly.Mechanical regulation of mesenchymal stem celldifferentiation[J].Journal of Anatomy,2015,227(6):717.
[14] McAndrews KM,McGrail DJ,Quach ND,et al.Spatially coordinated changes inintracellularrheology and extracellular force exertion during mesenchymal stem celldifferentiation[J].Phys Biol,2014,11(5):056004
[15] Phillips A M.Overview of the fracture healing cascade[J].Injury,2005,36(3):S5-S7.
[16] Wehner T,Wolfram U,Henzler T,et al.Internal forces and moments in the femur of the rat during gait[J].J Biomech,2010,43(13):2473-2479.
[17] Boerckel JD,Kolambkar Y,Stevens HY,et al.Effects of in vivo mechanicalloading on large bone defect regeneration[J].J OrthopRes,2012,30(7):1067-1075.
[18] Piatkowski K,Piekarczyk P,Kwiatkowski K,et al.Comparison ofdifferentlocking plate fixation methods in distal tibia fractures[J].Int Orthop,2015,39(11):2245-2251.
[19] 曾炳芳,康庆林.四肢骨不连外科学[M].北京:人民军医出版社,2010:23-25

备注/Memo

备注/Memo:
基金项目:国家自然科学基金资助项目(81373661) 山东省科技发展计划资助项目(2013G0021806)
更新日期/Last Update: 2018-01-15