[1]凯沙尔·百合提亚尔,陈殿卿,张磊,等.三维打印截骨导板对膝关节置换平衡功能的影响[J].中国中医骨伤科杂志,2024,32(02):32-37.[doi:10.20085/j.cnki.issn1005-0205.240206]
 CAESAR Lilytyar CHEN Dianqing ZHANG Lei NUERMAIMAITI Ainiwaer YANG Deyong SHU Li.The Efficacy of Three-Dimensional Printed Personalized Osteotomy Guide Technology on the Balance Function of Total Knee Arthroplasty[J].Chinese Journal of Traditional Medical Traumatology & Orthopedics,2024,32(02):32-37.[doi:10.20085/j.cnki.issn1005-0205.240206]
点击复制

三维打印截骨导板对膝关节置换平衡功能的影响()
分享到:

《中国中医骨伤科杂志》[ISSN:1005-0205/CN:42-1340/R]

卷:
第32卷
期数:
2024年02期
页码:
32-37
栏目:
临床研究
出版日期:
2024-02-15

文章信息/Info

Title:
The Efficacy of Three-Dimensional Printed Personalized Osteotomy Guide Technology on the Balance Function of Total Knee Arthroplasty
文章编号:
1005-0205(2024)02-0032-06
作者:
凯沙尔·百合提亚尔1陈殿卿2张磊3努尔买买提·艾尼瓦尔1杨德勇1舒莉1△
1新疆医科大学第六附属医院(乌鲁木齐,830002); 2武警河北总队医院; 3武警兵团总队医院
Author(s):
CAESAR Lilytyar1 CHEN Dianqing2 ZHANG Lei3 NUERMAIMAITI Ainiwaer1 YANG Deyong1 SHU Li1△
1Sixth Affiliated Hospital of Xinjiang Medical University,Urumqi 830002,China; 2Affiliated Hospital of Hebei Chinese People's Armed Police Forces,Shijiazhuang 050081,China; 3Affiliated Hospital of Xinjiang Production and Construction Corps of Chinese People's Armed Police Forces,Urumqi 830063,China.
关键词:
全膝关节置换术 三维打印 截骨导板 传统方法 本体感觉 平衡能力
Keywords:
total knee arthroplasty three-dimensional print personalized osteotomy guide conventional instrumentation proprioception balance function
分类号:
R687.4
DOI:
10.20085/j.cnki.issn1005-0205.240206
文献标志码:
A
摘要:
目的:比较三维(3D)打印截骨导板技术与传统全膝关节置换术后下肢本体感觉及平衡功能的差异。方法:50例因重度骨关节炎拟行初次单侧全膝关节置换的患者,用随机数字法分为3D打印截骨导板组和传统手术组,每组各25例。术前两组患者年龄、性别、体重指数、畸形程度差异均无统计学意义(P>0.05)。比较两组患者术后冠状面髋-膝-踝角(HKA)偏差值、冠状面股骨假体组件角偏差值、冠状面胫骨假体组件角偏差值、股骨后髁角(PCA)、髌骨横轴-股骨通髁线角(PFA); 比较两组术后3个月美国膝关节协会评分(KSS)临床评分、KSS功能评分、西安大略和麦克马斯特大学(WOMAC)骨关节炎指数评分和膝关节活动度; 用P-K252平衡仪评估患者本体感觉及平衡能力差异。结果:两组病例均未出现严重并发症。3D打印截骨导板组冠状面股骨假体偏差值、股骨后髁角及PFA小于传统手术组,差异有统计学意义(P<0.05); 3D打印截骨导板组KSS功能评分优于传统手术组,差异有统计学意义(P<0.05); 3D打印截骨导板组运动轨迹面积、运动轨迹周长小于传统手术组,差异有统计学意义(P<0.05); Berg Balance Scale(BBS)评分大于传统手术组,差异有统计学意义(P<0.05)。两组患者髋-膝-踝角偏差值、冠状面胫骨假体偏差值差异无统计学意义(P>0.05); 两组患者KSS临床评分、WOMAC评分、膝关节活动度和平均摆动数值差异无统计学意义(P>0.05)。结论:全膝关节置换术应用3D打印截骨导板能够获得更好的下肢稳定性。
Abstract:
Objective:To evaluate the proprioception and balance function of total knee arthroplasty between 3D printing personalized osteotomy guide technology and conventional instrumentation.Methods:50 patients with primary unilateral total knee arthroplasty were randomly divided into 3D printing personalized osteotomy guide technology group and conventional instrumentation group,25 patients in each group.There was no statistically significant difference in age,gender,body mass index,and degree of deformity between the two groups preoperative.The hip-knee-ankle angle(HKA),coronal femoral component component angle deviation,coronal tibial component component angle deviation,posterior femoral condyle(PCA)and transverse axis of patella to femoral condyle line angle(PFA)were compared between the two groups.The knee society scores(KSS)clinical score,KSS functional score,Western Ontario and McMaster Universities(WOMAC)score,and knee joint range of motion were compared between the two groups at 3 months after surgery.P-K252 balancing apparatus was used to evaluate the difference in proprioception and stability of patients.Results:There were no serious complications in both groups.The coronal femoral prosthesis deviation,PCA and PFA in the 3D printed osteotomy guide group were less than those in conventional instrumentation group(P<0.05).The KSS functional score of the 3D printed osteotomy guide plate group was better than conventional instrumentation group(P<0.05).The motion track area and motion track perimeter of the 3D printed osteotomy guide plate group were smaller than conventional instrumentation group(P<0.05),and the Berg Balance Scale(BBS)score was higher than that of conventional instrumentation group(P<0.05).There were no significant difference in HKA deviation and coronal plane tibial prosthesis deviation between the two groups(P<0.05).There were no significant differences in KSS clinical score,WOMAC score,knee joint range of motion and average swing value and knee motion between the two groups(P>0.05).Conclusion:The application of 3D printed personalized osteotomy guide plate in total knee replacement can achieve better lower limb stability in this study.

参考文献/References:

[1] 郭子文,彭锐,宋建东.中药防治膝骨性关节炎的作用机制研究进展[J].中国中医骨伤科杂志,2021,29(12):85-88.
[2] 张虎林,喻琳,王亮,等.膝骨性关节炎关键信号通路的研究进展[J].中国中医骨伤科杂志,2021,29(10):84-88.
[3] 乔桦,李慧武.膝关节置换手术机器人应用现状与研究进展[J].山东大学学报(医学版),2023,61(3):29-36.
[4] 高峰,徐锋,吴晓峰,等.全膝关节置换术治疗老年膝骨关节炎的临床疗效[J].临床骨科杂志,2023,26(2):193-197.
[5] 陆声,辛欣,黄文华,等.3D打印骨科手术导板的临床应用进展[J].南方医科大学学报,2020,40(8):1220-1224.
[6] 韩衍龙,哈巴西·卡肯,赵巍,等.3D打印技术辅助全膝关节置换临床疗效的Meta分析[J].生物骨科材料与临床研究,2021,18(5):47-56.
[7] 安贵峰,王明月.3D 打印截骨导板在人工全膝关节置换术中的临床应用研究[J].中国实用医药,2020,15(17):98-100.
[8] 裴福兴,陈安民.骨科学[M].北京:人民卫生出版社,2016:102-103.
[9] 郑绍敏,林坚,黄墩兵,等.视觉反馈下本体感觉训练对早期全膝关节置换术后患者平衡功能的影响[J].浙江医学,2021,43(6):630-634.
[10] 余浪波.3D 打印个性化截骨导板在全膝关节置换术中的研究进展[J].东南国防医药,2020,22(4):403-406.
[11] 柴浩,杨德勇,张磊,等.3D 打印个性化截骨导板与传统全膝关节置换下肢力线准确性对比的 Meta 分析[J].中国组织工程研究,2023,27(4):646-654.
[12] 宋强,刘泽欣,张强,等.传统技术和3D打印个性化截骨导板辅助下全膝关节置换术治疗膝骨关节炎的对比研究[J].中华骨与关节外科杂志,2023,16(5):461-465.
[13] 李瑾,宋佳凝,李健,等.本体感觉训练联合肌内效贴对全膝关节置换术后患者膝关节功能与本体感觉的影响[J].中国康复,2022,37(3):145-148.
[14] 卢岩岩,许学猛,刘文刚,等.本体感觉和平衡训练对全膝关节置换后膝关节功能恢复影响 Meta分析[J].中国组织工程研究,2019,23(16):2601-2607.
[15] 李昌钊,陈加荣,李凭跃.全膝关节置换术后膝前痛与髌股关节的关系及髌股关节异常的影响因素[J].中华骨科杂志,2019,39(23):1470-1477.
[16] 冉学军,余江,胡兆洋,等.全膝关节置换术中假体精准旋转对位的重要性[J].中国骨与关节损伤杂志,2020,35(12):1292-1293.
[17] SUN M L,ZHANG Y,PENG Y,et al.Gait analysis after total knee arthroplasty assisted by 3D-printed personalized guide[J].Bio Med Research International,2020,30:6485178.
[18] 杨军港,谭勇海,宋修刚,等.三维打印截骨导板技术在膝内翻畸形全膝关节置换术中的应用[J].中国中医骨伤科杂志,2022,30(9):67-71.
[19] 赵春涛,卿明松,彭笳宸.运动学对线应用于全膝关节置换术的研究进展[J].天津医药,2020,48(3):236-240.
[20] 王强,周强.运动力学对线截骨对全膝关节置换术后运动学、生物力学及膝关节功能的影响[J].中华骨与关节外科杂志,2021,14(11):916-922.
[21] BLAKENEY W,CLÉMENT J,DESMEULES F,et al.Kinematic alignment in total knee arthroplasty better reproduces normal gait than mechanical alignment[J].Knee Surg Sports Traumatol Arthrosc,2019,27(5):1410-1417.
[22] 赵春涛,卿明松,彭笳宸.运动学对线应用于全膝关节置换术的研究进展[J].天津医药,2020,48(3):236-240.
[23] 陈能,吕燃,马少云,等.膝骨关节炎患者全膝关节置换术后本体感觉的研究进展[J].风湿病与关节炎,2019,8(5):63-67.

备注/Memo

备注/Memo:
基金项目:新疆维吾尔自治区卫生健康青年医学科技人才专项科研项目(WJWY-202024)
通信作者 E-mail:865738523@qq.com
更新日期/Last Update: 2024-02-15