[1]李照文,李绪贵△,李培金,等.倾角测量器在全髋关节置换术中的应用研究[J].中国中医骨伤科杂志,2024,32(01):65-70.[doi:10.20085/j.cnki.issn1005-0205.240112]
 LI Zhaowen,LI Xugui,LI Peijin,et al.Research on the Application of Inclinometer in Total Hip Arthroplasty[J].Chinese Journal of Traditional Medical Traumatology & Orthopedics,2024,32(01):65-70.[doi:10.20085/j.cnki.issn1005-0205.240112]
点击复制

倾角测量器在全髋关节置换术中的应用研究()
分享到:

《中国中医骨伤科杂志》[ISSN:1005-0205/CN:42-1340/R]

卷:
第32卷
期数:
2024年01期
页码:
65-70
栏目:
临床论著
出版日期:
2024-01-15

文章信息/Info

Title:
Research on the Application of Inclinometer in Total Hip Arthroplasty
文章编号:
1005-0205(2024)01-0065-06
作者:
李照文1李绪贵1△李培金1叶劲1左昌俊1王威1唐园1
1武汉中西医结合骨科医院(武汉体育学院附属医院)(武汉,430079)
Author(s):
LI Zhaowen1LI Xugui1△LI Peijin1YE Jing1ZUO Changjun1WANG Wei1TANG Yuan1
1Wuhan Orthopaedic Hospital of Integrated Traditional Chinese and Western Medicine(Affiliated Hospital of Wuhan Sports University),Wuhan 430079,China.
关键词:
全髋关节置换术 外展角 前倾角 自设计倾角测量器
Keywords:
total hip arthroplasty abduction angle anteversion angle self-designed inclination angle measuring device
分类号:
R687.4
DOI:
10.20085/j.cnki.issn1005-0205.240112
文献标志码:
A
摘要:
目的:探讨应用自设计臼杯倾角测量器来辅助提高全髋关节置换术(THA)中髋臼臼杯置入角度(外展角和前倾角)的精准度。方法:选择2021年9月至2023年5月30例因髋关节疾病行全髋关节置换术治疗的患者,按随机分组法分为观察组(术中采用臼杯倾角测量器来测量髋臼臼杯所置入的外展角和前倾角,15例)和传统组(传统全髋关节置换术组,15例),两组术前规划其髋臼臼杯置入的外展角为40°、前倾角为20°,术后X线片测量两组臼杯假体的外展角和前倾角与术前规划的差异。结果:观察组术后髋臼臼杯外展角和前倾角与术前所规划角度之间的误差明显小于传统组,且组间差异有统计学意义(P<0.05)。结论:在全髋关节置换术中,采用臼杯倾角测量器对髋臼臼杯置入的外展角和前倾角进行测量与校正,能提高髋臼臼杯置入角度(外展角和前倾角)的精准度。
Abstract:
Objective:To investigate the application of a self-designed device for measuring the cup inclination angle in order to enhance the accuracy of acetabular cup placement angles(abduction angle and anteversion angle)during total hip arthroplasty(THA).Methods:30 patients who underwent THA for hip joint diseases from September 2021 to May 2023 were selected were randomly divided into two groups:an observation group(15 cases)and a traditional group(15 cases).In the observation group,the cup inclination angle measurement device was used during the surgery to measure the abduction angle and anteversion angle of the acetabular cup placement,whereas the traditional group underwent the conventional THA procedure.The planned abduction and anteversion angles for both groups were set at 40° and 20° respectively.Postoperative X-ray films were utilized to measure the disparity between the actual abduction and anteversion angles of the acetabular cup prosthesis in each group and the preoperative planned angles.Results:The observation group demonstrated significantly smaller errors between the postoperative abduction angle,anteversion angle,and the preoperative planned angles compared to the traditional group.A statistically significant difference was observed between the two groups(P<0.05).Conclusion:In THA procedures,the implementation of the cup inclination angle measurement device to assess and correct the abduction angle and anteversion angle of the acetabular cup placement can notably improve the accuracy of the cup placement angles.

参考文献/References:

[1] PFLÜGER M J,FRÖMEL D E,MEURER A.Total hip arthroplasty revision surgery:impact of morbidity on perioperative outcomes[J].J Arthroplasty,2021,36(2):676-681.
[2] 刘建友,贾中伟,牛佳伟,等.构建股骨3D数字化模型提出一种新的股骨颈前倾角测量方法[J].中国组织工程研究,2021,25(24):3779-3783.
[3] SEAGRAVE K G,TROELSEN A,MALCHAU H,et al.Acetabular cup position and risk of dislocation in primary total hip arthroplasty[J].Acta Orthopaedica,2017,88(1):10-17.
[4] 范广,向川.髋臼假体置入角度对髋关节功能的影响[J].实用骨科杂志,2019,25(8):740-743.
[5] 柯岩,李志昌,罗松曲珠,等.5G远程机器人辅助全髋关节置换术治疗大骨节病致髋关节病变[J].中华骨科杂志,2023,43(1):9-15.
[6] 侯文渊,朱磊,顾一帆,等.骨痹通消颗粒治疗早中期非创伤性股骨头坏死40例[J].中国中医骨伤科杂志,2023,31(1):56-60.
[7] 毕红宾,杨亚丽,李岩,等.直接前侧入路小切口病灶清除打压植骨治疗股骨头坏死的疗效[J].中国中医骨伤科杂志,2023,31(3):67-71.
[8] 杨飞,王国栋,马辉,等.全髋关节置换术后翻修的原因分析[J].中国骨与关节损伤杂志,2020,35(6):561-564.
[9] BARRACK R L.Dislocation after total hip arthroplasty:implant design and orientation[J].J Am Acad Orthop Surg,2003,11(2):89-99.
[10] SHOJI T,INOUE T,KATO Y,et al.Associations between implant alignment or position and patient-reported outcomes after total hip arthroplasty[J].Clin Biomech(Bristol,Avon),2022,97:105701.
[11] THORNE T,NISHIOKA S,ANDREWS S,et al.Component placement accuracy of two digital intraoperative fluoroscopy supplementation systems in direct anterior total hip arthroplasty[J].Arch Orthop Trauma Surg,2022,142(6):1283-1288.
[12] SHIGEMURA T,BABA Y,MURATA Y,et al.Is a portable accelerometer-based navigation system useful in total hip arthroplasty?A systematic review and meta-analysis[J].Orthop Traumatol Surg Res,2021,107(1):102742.
[13] 田润,雷雨田,王坤正,等.机器人辅助人工全髋关节置换术中及术后测量髋臼角度比较研究[J].中国修复重建外科杂志,2021,35(10):1246-1250.
[14] KHALIFA A A,ABDELNASSER M K,AHMED A M,et al.Smartphone application helps improve the accuracy of cup placement by young,less-experienced surgeons during primary total hip arthroplasty[J].Arch Bone Jt Surg,2022,10(3):278-285.
[15] 严亮,王彭,周海斌.3D打印导板在发育性髋关节发育不良全髋关节置换术中的应用[J].中国骨伤,2020,33(11):1001-1005.
[16] PENENBERG B L,SAMAGH S P,RAJAEE S S,et al.Digital radiography in total hip arthroplasty:technique and radiographic results[J].J Bone Joint Surg Am,2018,100(3):226-235.
[17] BAKSH N,WEI L,HO E S,et al.Radiation exposure in fluoroscopy-guided anterior total hip arthroplasty:a systematic review[J].Eur J Orthop Surg Traumatol,2022,32(5):891-897.
[18] 张强,杜俊炜,戴志兵,等.3D打印定制半骨盆假体置换治疗原发性髋臼周围恶性肿瘤的疗效评估[J].实用骨科杂志,2022,28(3):203-208.
[19] HALUZYNSKYI O A,CHORNYI V S,BURBURSKA S V,et al.Use of computer navigation in total hip arthroplasty(literature review)[J].Wiad Lek,2022,75(6):1765-1770.
[20] 涂源源,万大地,汪群力.机器人辅助与传统人工全髋关节置换术后下肢长度差异的Meta分析[J].中国修复重建外科杂志,2022,36(5):561-566.

备注/Memo

备注/Memo:
基金项目:武汉市卫健委科研基金资助项目(WX21C04)
通信作者 E-mail:gojing301@163.com
更新日期/Last Update: 2024-01-15