[1]胡锋,刘艳西,叶茂,等.试模复位技术定位胫骨假体旋转对线的临床研究[J].中国中医骨伤科杂志,2023,31(07):34-38+47.[doi:10.20085/j.cnki.issn1005-0205.230707 ]
 HU Feng,LIU Yanxi,YE Mao,et al.A Clinical Study on Rotational Positioning of Tibial Components by the ROM Technique[J].Chinese Journal of Traditional Medical Traumatology & Orthopedics,2023,31(07):34-38+47.[doi:10.20085/j.cnki.issn1005-0205.230707 ]
点击复制

试模复位技术定位胫骨假体旋转对线的临床研究()
分享到:

《中国中医骨伤科杂志》[ISSN:1005-0205/CN:42-1340/R]

卷:
第31卷
期数:
2023年07期
页码:
34-38+47
栏目:
临床研究
出版日期:
2023-07-15

文章信息/Info

Title:
A Clinical Study on Rotational Positioning of Tibial Components by the ROM Technique
文章编号:
1005-0205(2023)07-0034-05
作者:
胡锋1刘艳西1叶茂1吴剑1陈俊1王峰2付志厚2△
1咸宁市中心医院(湖北科技学院附属第一医院)关节外科(湖北 咸宁,437100)
2中国人民解放军联勤保障部队第960医院骨科
Author(s):
HU Feng1LIU Yanxi1YE Mao1WU Jian1CHEN Jun1WANG Feng2FU Zhihou2△
1Department of Joint Surgery,Xianning Central Hospital(The First Affiliated Hospital of Hubei University of Science and Technology),Xianning 437100,Hubei China; 2Orthopedic Department,The 960 Hospital of PLA,Jinan 250031,China.
关键词:
全膝关节置换术 胫骨假体 旋转定位
Keywords:
total knee arthroplasty tibial component rotational positioning
分类号:
R687.4
DOI:
10.20085/j.cnki.issn1005-0205.230707
文献标志码:
A
摘要:
目的:探讨轻中度膝内外翻患者行全膝关节置换术(Total Knee Arthroplasty,TKA)时运用试模复位技术确定胫骨假体旋转定位区间及旋转对线的临床疗效。方法:选取2019年10月至2022年3月62例行初次单侧全膝关节置换术的患者,术中运用试模复位技术进行胫骨旋转定位,术后随访采用膝关节活动度、美国膝关节协会评分(KSS评分)评价临床效果,行CT扫描并测量胫骨假体旋转角度及假体旋转不匹配度。结果:胫骨假体相对于胫骨结节内侧缘处于外旋位,平均旋转角度α1=7.43°±3.18°; 胫骨假体相对于胫骨结节中、内侧缘1/3处于内旋位,平均旋转角度α2=-13.12°±4.38°; 股骨和胫骨假体旋转不匹配角度β角平均为2.42°±4.17°。随访时间为6~18 个月,平均为(12.31±2.15)个月,62例患者均未出现手术相关并发症,术后膝关节活动度为115.63°±6.98°,KSS临床评分为(90.02±2.92)分,功能评分为(83.22±6.41)分,与术前差异有统计学意义(P<0.05)。结论:轻中度膝内外翻患者行全膝关节置换手术时运用试模复位技术确定胫骨假体的旋转定位可以获得良好的临床效果,其定位区间位于胫骨结节内侧缘与胫骨结节中、内侧缘1/3之间。
Abstract:
Objective:To explore the clinical efficacy and range of tibial rotational alignment using the range of motion(ROM)technique for determining the rotational alignment of the tibial prosthesis in cases of mild to moderate varus and valgus deformity in total knee arthroplasty(TKA).Methods:A retrospective study was conducted on 62 patients who underwent TKA between October 2019 and March 2022.The tibial component was positioned using the ROM technique.The rotational alignment of the tibial component was measured on CT images with reference to the medial aspect of the tibial tubercle and the medial one-third of the tibial tubercle.The range of motion and knee society score(KSS)were used to assess the clinical outcomes.Results:The rotational alignment of the tibial component was found to be 7.43°±3.18° relative to the medial aspect of the tibial tubercle and -13.12°±4.38° relative to the medial one-third of the tibial tubercle.There was a significant difference between the two groups(P<0.05).The rotational mismatch was measured to be 2.42°±4.17°.The follow-up period ranged from 6 to 18 months,with an average of(12.31±2.15)months.No postoperative complications were observed.The ROM was recorded as 115.63°±6.98°.The clinical postoperative KSS scores were(90.02±2.92)points,and the functional KSS scores were(83.22±6.41)points.Conclusion:The use of the ROM technique for positioning the tibial rotational alignment in cases of mild to moderate varus and valgus deformity in TKA has shown promising clinical efficacy.The ideal range of tibial rotational alignment in TKA was found to be from the medial border of the tibial tubercle to the medial one-third of the tibial tubercle.Employing the ROM technique for tibial rotational alignment facilitates a more suitable matching of the tibial component with the femoral component and provides reliable tibiofemoral joint dynamics characteristics.

参考文献/References:

[1] MATZ J,LANTING B A,HOWARD J L.Understanding the patellofemoral joint in total knee arthroplasty[J].Can J Surg,2019,62(1):57-65.
[2] TANIKAWA H,TADA M,OGAWA R,et al.Influence of patella thickness on patellofemoral pressure in total knee arthroplasty[J].BMC Musculoskelet Disord,2021,22(1):298.
[3] 中华医学会骨科学分会关节外科学组.骨关节炎诊治指南(2018 年版)[J].中华骨科杂志,2018,38(12):705-715.
[4] PANNI A S,ASCIONE F,ROSSINI M,et al.Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty:a systematic review[J].Knee Surg Sports Traumatol Arthrosc,2018,26(6):1636-1644.
[5] VALKERING K P,BREUGEM S J,VAN DEN BEKEROM M P,et al.Effect of rotational alignment on outcome of total knee arthroplasty[J].Acta Orthop,2015,86(4):432-439.
[6] SAILHAN F,JACOB L,HAMADOUCHE M.Differences in limb alignmentand femoral mechanical-anatomical angles using two dimensionversus three dimension radiographic imaging[J].Int Orthop,2017,4(10):2009-2016.
[7] SAFFARINI M,NOVER L,TANDOGAN R,et al.The original Akagi line is the most reliable:a systematic review of landmarks for rotational alignment of the tibial component in TKA[J].Knee Surg Sports Traumatol Arthrosc,2019,27(4):1018-1027.
[8] KAWAGUCHI K,INUI H,TAKETOMI S,et al.Intraoperative tibial anteroposterior axis could not be replicated after tibial osteotomy in total knee arthroplasty[J].J Arthroplasty,2019,34(10):2371-2375.
[9] KIM J I,JANG J,LEE K W,et al.Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty[J].BMC Musculoskelet Disord,2017,18(1):252-257.
[10] POPESCU R,HARITINIAN E G,CRISTEA S.Methods of intra- and post-operative determination of the position of the tibial component during total knee replacement[J].Int Orthop,2020,44(1):119-128.
[11] INSALL J N.Surgical technique and instrumentation in TKA [M].in:INSALL J N,ed.Surgery of the Knee.New York:Churchill Livingstone,1993:739-893.
[12] 孙振辉,孙云波,任志帅,等.Gemini MK-Ⅱ活动垫片膝关节假体置换术中胫骨结节内1/3解剖定位法对胫骨假体旋转力线的影响[J].中国修复重建外科杂志,2015,29(9):1062-1066.
[13] DREXLER M,BACKSTEIN D,STUDLER U,et al.The medial border of the tibial tuberosity as an auxiliary tool for tibial component rotational alignment during total knee arthroplasty(TKA)[J].Knee Surg Sports Traumatol Arthrosc,2017,25(6):1736-1742.
[14] UEHARA K,KADOYA Y,KOBAYASHI A,et al.Bone anatomy and rotational alignment in total knee arthroplasty[J].Clin Orthop Relat Res,2002,402:196-201.
[15] OKAZAKI Y,PUJOL N.The use of an asymmetrical tibial tray in TKA optimises tibial rotation when fitted to the posterior tibial plateau border[J].Knee Surg Sports Traumatol Arthrosc,2020,28(12):3821-3826.
[16] BAE J H,LEE J W,KIM S H,et al.Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty[J].Knee Surg Sports Traumatol Arthrosc,2022,30(2):698-704.
[17] IKEUCHI M,YAMANAKA N,OKANOUE Y,et al.Determining the rotational alignment of the tibial component at total knee replacement:a comparison of two techniques[J].J Bone Joint Surg(Sr),2007,89(1):45-49.
[18] GRASSI A,PIZZA N,LOPOMO N F,et al.No differences in knee kinematics between active and passive flexion-extension movement:an intra-operative kinematic analysis performed during total knee arthroplasty[J].J Exp Orthop,2020,7(1):12.
[19] LEE D H,SEO J G,MOON Y W.Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty[J].Int Orthop,2008,32(2):223-227.
[20] KESSLER O,LACATUSU E,SOMMERS M B,et al.Malrotation in total knee arthroplasty:effect on tibial cortex strain captured by laser-based strain acquisition[J].Clin Biomech(Bristol,Avon),2006,21(6):603-609.

备注/Memo

备注/Memo:
通信作者 E-mail:jzgbfzh@yahoo.com.cn
更新日期/Last Update: 2023-07-10