模拟腰椎关节松动手法及冲击手法下椎间盘应变的比较()
分享到:

《中国中医骨伤科杂志》[ISSN:1005-0205/CN:42-1340/R]

卷:
第27卷
期数:
2019年10期
页码:
1-4
栏目:
实验研究
出版日期:
2019-10-10

文章信息/Info

Title:
Comparison of Human Lumbar Disc Strain during Simulated Spinal Manipulation versus Spinal Mobilization
文章编号:
1005-0205(2019)10-0001-04
作者:
王飞1 张军2△ 卫杰1 郭伟1 韩磊1 刘强2 赵平1△
1空军特色医学中心中西医结合正骨科(北京,100142) 2中国中医科学院望京医院筋伤手法治疗研究室
Author(s):
WANG Fei1 ZHANG Jun2△ WEI Jie1 GUO Wei1 HAN Lei1 LIU Qiang2 ZHAO Ping1△
1Department of TCM Manipulative Orthopedics,Air Force Medical Center of PLA,Beijing 100142,China; 2Department of Sinew Injury Manual Therapy Research,Wangjing Hospital of China Academy of Chinese Medical Sciences,Beijing 100102,China.
关键词:
松动手法 冲击手法 腰椎 椎间盘 应变
Keywords:
mobilization thrusting manipulation lumbar spine intervertebral disc strain
分类号:
R318
文献标志码:
A
摘要:
目的:了解模拟腰椎关节松动手法和冲击手法下椎间盘应变的变化特征,探讨两种手法对椎间盘应变作用的异同。方法:12具成年男性新鲜尸体腰椎标本(T12~S2)随机分为两组。一组模拟松动手法(n=6):预加载15°,速度3°/s,最大加载角度20°,速度1°/s,L5棘突水平加载9 N.另一组模拟冲击手法(n=6):预加载15°,速度3°/s,最大加载角度20°,冲击速度33°/s,L5棘突水平加载22 N.于标本前面喷涂散斑,采用非接触应变测量系统采集手法全过程的图像。通过ARAMIS软件计算,自动输出Von Mises应变云图。结果:模拟两种手法过程中,腰椎旋转时椎间盘应变逐渐增大,回复过程中椎间盘应变逐渐减小,模拟冲击手法椎间盘应变变化速度更快; 模拟两种手法下无论L4~5还是L5S1椎间盘最大应变差异均无统计学意义(P>0.05); 每种手法下L4~5和L5S1椎间盘最大应变差异无统计学意义(P>0.05)。结论:模拟腰椎关节松动手法和冲击手法下椎间盘最大应变无差异。
Abstract:
Objective:The present study aimed to investigate the differences in human lumbar disc strain during simulated spinal manipulation and spinal mobilization.Methods:A total of 12 adult fresh lumbar spinal specimens(T12~S2)were randomly divided into two groups.The parameters of simulated spinal mobilization were as follows:Preload angle,15°(speed,3°/s); maximum angle,20°(speed,1°/s); and 9 N horizontal force to the L5 spinous process.The parameters of simulated spinal manipulation were as follows:Preload angle,15°(speed,3°/s); impulse angle,20°(impulse speed,33°/s)and 22 N horizontal force to the L5 spinous process.Disc strain was measured by non-contact strain measurement system after speckle was sprained on the anterior surface of the specimens.It was obtained with software ARAMIS,and Von Mises strain nephograms were also output.Results:Strain on discs ascended first and then descended gently during mobilization,while it ascended quickly to peak during manipulation.There was no difference of maximal strain on discs during two techniques(P>0.05).There was no difference of maximal strain between L4~5and L5~S1 discs in either group(P>0.05).Conclusion:There is no difference of maximal strain on discs during simulated mobilization and manipulation.

参考文献/References:

[1] HENDERSON C N.The basis for spinal manipulation:chiropractic perspective of indications and theory[J].J Electromyogr Kinesiol,2012,22(5):632-642.[2] 刘强,王飞,张军.关节突关节压力负荷的生物力学研究进展[J].中医正骨,2016,28(1):72-75. [3] AVRAMOV A I,CAVANAUGH J M,OZAKTAY C A,et al.The effects of controlled mechanical loading on group-Ⅱ,Ⅲ and Ⅳ afferent units from the lumbar facet joint and surrounding tissue:an in vitro study[J].J Bone Joint Surg Am,1992,74(10):1464-1471. [4] 毕胜,李义凯,汪爱媛,等.不同推拿手法下腰椎小关节应力变化的观察[J].中国康复医学杂志,2001,16(3):144-145 [5] HERZOG W.The biomechanics of spinal manipulation[J].J Bodyw Mov Ther,2010,14(3):280-286. [6] DOWNIE A S,VEMULPAD S,BULL P W.Quantifying the high-velocity,low-amplitude spinal manipulative thrust:a systematic review[J].J Manipulative Physiol Ther,2010,33(7):542-553. [7] 张军,王飞,刘强,等.腰椎关节松动手法及冲击手法下力在关节突关节内的传导特征[J].中国组织工程研究,2016,20(17):2546-2554. [8] 张军,刘强,孙树椿,等.基于退变腰椎间盘模型的旋转手法对椎体角度位移的影响[J].中国中医骨伤科杂志,2016,24(5):1-4. [9] MAIGNE J Y,GUILLON F.Highlighting of intervertebral movements and variations of intradiskal pressure during lumbar spine manipulation:a feasibility study[J].J Manipulative Physiol Ther,2000,23(8):531-535. [10] 马信龙,马剑雄,徐卫国,等.骨科生物力学研究的测量方法专家共识[J].中国骨质疏松杂志,2014,20(9):1039-1054. [11] TANASIC I,MILIC-LEMIC A,TIHACEK-SOJIC L,et al.Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method[J].Biomech Model Mechanobiol,2012,11(6):751-758. [12] HSU V M,WES A M,TAHIRI Y,et al.Quantified facial soft-tissue strain in animation measured by real-time dynamic 3-dimensional imaging[J].Plast Reconstr Surg Glob Open,2014,2(9):e211. [13] 张人文,莫灼锚,唐树杰.腰椎间盘突出症治疗手法的有限元研究现状[J].中国中医骨伤科杂志,2018,26(1):81-83. [14] AMIN D B,MOAWAD C M,COSTI J J.New findings confirm regional internal disc strain changes during simulation of repetitive lifting motions[J].Annals of Biomedical Engineering,2019,47(6):1378-1390. [15] CHAUDHRY H,JI Z,SHENOY N,et al.Viscoelastic stresses on anisotropic annulus fibrosus of lumbar disk under compression,rotation and flexion in manual treatment[J].J Bodyw Mov Ther,2009,13(2):182-191. [16] 徐海涛,张美超,李义凯,等.坐位旋转手法对正常腰椎间盘内在应力和位移的实时监测的实验研究[J].中国康复医学杂志,2005,20(8):563-565. [17] 张勇,毕胜.腰椎旋转手法对髓核内压力和神经根位移的影响[J].颈腰痛杂志,2001,22(3):184-186.