[1]王河忠 刘洋 谭俊峰△.聚醚醚酮棒半刚性固定系统在腰椎融合术中的应用[J].中国中医骨伤科杂志,2020,28(04):36-40.
 WANG Hezhong LIU Yang TAN Junfeng.Clinical Application of Polyetheretherketone Rod Semi-rigid Fixation System in Lumbar Fusion[J].Chinese Journal of Traditional Medical Traumatology & Orthopedics,2020,28(04):36-40.
点击复制

聚醚醚酮棒半刚性固定系统在腰椎融合术中的应用()
分享到:

《中国中医骨伤科杂志》[ISSN:1005-0205/CN:42-1340/R]

卷:
第28卷
期数:
2020年04期
页码:
36-40
栏目:
临床研究
出版日期:
2020-04-06

文章信息/Info

Title:
Clinical Application of Polyetheretherketone Rod Semi-rigid Fixation System in Lumbar Fusion
文章编号:
1005-0205(2020)04-0036-05
作者:
王河忠1 刘洋1 谭俊峰1△
1武汉市第五医院(江汉大学第二附属医院)骨科(武汉,430050)
Author(s):
WANG Hezhong1 LIU Yang1 TAN Junfeng1△
1Department of Orthopedics, the Fifth Hospital of Wuhan(the Second Hospital Affiliated of Jianghan University), Wuhan 430050, China.
关键词:
聚醚醚酮棒 钛棒 腰椎融合术
Keywords:
polyetheretherketone rod titanium rod lumbar interbody fusion
分类号:
R681.5
文献标志码:
A
摘要:
目的:比较聚醚醚酮(PEEK)棒半刚性固定系统和钛棒刚性固定系统在腰椎融合术中的临床疗效。 方法:回顾性分析2015年6月至2018年6月行后路椎间植骨融合术(PLIF)治疗腰椎退变性疾病患者54例,按照内固定材料分为两组(PEEK棒组27例,钛棒组27例)。其中男18例,女36例; 年龄52~72岁,平均(54.6±4.3)岁。所有患者术前均行腰椎正侧位X线片、腰椎过伸过屈X线片、CT平扫、腰椎MRI检查。通过比较两组患者术前及术后3,6,12个月Oswestry功能障碍指数(ODI)和日本骨科学会(JOA)评分评价临床疗效。术后3,6,12个月通过Brantigan椎间融合标准评价植骨融合情况。 结果:54例患者术后均得到随访,随访时间12~24个月,平均(16.4±4.2)个月。所有患者均未出现伤口感染、脑脊液漏、内固定松动及断裂等并发症。术后3,6,12个月两组患者ODI均呈下降趋势,两组间差异无统计学意义(P>0.05); 术后3,6,12个月两组患者JOA评分均呈上升趋势,两组间差异无统计学意义(P>0.05)。术后3个月PEEK棒组融合率高于钛棒组,两组间差异有统计学意义(P<0.05); 术后6个月两组患者融合率均为100%,两组间差异无统计学意义(P>0.05)。结论:PEEK棒半刚性固定系统与钛棒内固定系统在腰椎融合术中均可取得良好临床疗效,但PPEK棒半刚性固定系统早期融合疗效更佳。
Abstract:
Objective:To compare the clinical efficacy of polyetheretherketone(PEEK)rod semi-rigid fixation system and titanium rod rigid fixation system in lumbar fusion. Methods:A retrospective analysis was performed on 54 patients who underwent posterior lumbar interbody fusion(PLIF)for the treatment of lumbar degeneration from June 2015 to June 2018 in our department. According to the internal fixation materials, the patients were divided into two groups: 27 patients in the PEEK rod group and 27 patients in the titanium rod group. There were 18 males and 36 females. The average age was 52~72 years old(54.6±4.3). All patients were received positive and lateral lumbar X-ray, lumbar hyperextension and hyperflexion X-ray, plain CT scan, and lumbar MRI before surgery. Oswestry dysfunction index(ODI)and Japanese Orthopedic Association(JOA)scores at 3, 6 and 12 months before and after surgery were compared between the two groups to evaluate the clinical efficacy. The bone graft fusion was evaluated by Brantigan intervertebral fusion criteria at 3, 6 and 12 months postoperatively. Results:All the 54 patients were followed up after surgery from 12 to 24 months, an average of(16.4±4.2)months. None of the patient had complications such as surgical incision infection, cerebrospinal fluid leakage, loosing or breaking internal fixation, and others complications. Oswestry dysfunction index of the two groups decreased at 3, 6 and 12 months after surgery, and the difference between the two groups was not statistically significant(P>0.05). Postoperative JOA scores of patients in the two groups showed an increasing trend at 3, 6 and 12 months after surgery, and the difference between the two groups was not statistically significant(P>0.05). 3 months after surgery, the fusion rate of PEEK stick group was higher than that of titanium stick group, and the difference between the two groups was statistically significant(P<0.05). 6 months after surgery, the fusion rate of the two groups was 100%, and there was no significant difference between the two groups(P>0.05). Conclusion:PEEK semi-rigid fixation system and titanium rod internal fixation system can achieve equal clinical efficacy in lumbar fusion. But the PEEK rods semi-rigid fixation system early fusion curative effect is better.

参考文献/References:

[1] 张威,杨克新,朱立国,等.Quadrant通道下MIS-TLIF与开放PLIF治疗腰椎退变性疾病的比较[J].中国矫形外科杂志,2018,26(19):1770-1774.
[2] 赵永辉,陆声,马宇龙,等.皮质骨通道螺钉技术在腰椎退变性疾病中的临床应用[J].中华老年骨科与康复电子杂志,2019,5(3):123-129.
[3] CHAMOLI U,DIWAN A D,TSAFNAT N.Pedicle screw-based posterior dynamic stabilizers for degenerative spine:in vitro biomechanical testing and clinical outcomes[J].J Biomed Mater Res Part A,2014,102(9):3324-3340.
[4] PAYER M,NICOLAS S,OEZKAN N,et al.Dynamic transpedicular stabilisation and decompression in single-level degenerative anterolisthesis and stenosis[J].Acta Neurochir,2014,156(2):221-227.
[5] GALBUSERA F,BELLINI C M,ANASETTI F,et al.Rigid and flexible spinal stabilization devices:a biomechanical comparison[J].Med Eng Phys,2011,33(4):490-496.
[6] LI C,LIU L,SHI J Y,et al.Clinical and biomechanical researchers of polyetheretherketone(PEEK)rods for semi-rigid lumbar fusion:a systematic review[J].Neur Rev,2018,41:375-389.
[7] VIEWEG U,SOLA S.Posterior lumbar interbody fusion with an interbody fusion spacer or cage[J].Manual of Spine Surgery,2012,4:377-384.
[8] HILIBRAND A S,ROBBINS M.Adjacent segment degeneration and adjacent segment disease:the consequences of spinal fusion?[J].Spine,2004,4(6):190-194.
[9] PARK P,GARTON H J,GALA V C,et al.Adjacent segment disease after lumbar or lumbosacral fusion:review of the literature[J].Spine(Phila Pa 1976),2004,29(17):1938-1944.
[10] MAVROGENIS A F,VOTTIS C,TRIANTAFYLLOPOULOS G,et al.PEEK rod systems for the spine[J].Eur J Orthop Surg Traumatol,2014,24:S111-S116.
[11] HUANG W,CHANG Z,SONG R,et al.Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases:clinical experience with a 2-year follow-up[J].BMC Musculoskelet Disord,2016,17:53.
[12] FU L,FRANCE A,XIE Y,et al.Functional and radiological outcomes of semi-rigid dynamic lumbar stabilization adjacent to single-level fusion after 2 years[J].Arch Orthop Trauma Surg,2014,134:605-610.
[13] LEQUIN M B,VERBAAN D,BOUMA G J.Posterior lumbar interbody fusion with stand-alone trabecular metal cages for repeatedly recurrent lumbar disc herniation and back pain[J].J Neurosurg Spine,2014,20:617-622.
[14] COLANGELI S,BARBANTI BRODANO G,GASBARRINI A,et al.Polyetheretherketone(PEEK)rods:short-term results in lumbar spine degenerative disease[J].J Neurosurg Sci,2015,59(2):91-96.
[15] JAHNG T A,KIM Y E.Comparison of the biomechanical effect of pedicle-based dynamic stabilization:a study using finite element analysis[J].Spine J,2013,13(1):85-94.
[16] ORMOND D R,ALBERT L J R,DAS K.Polyetheretherketone(PEEK)rods in lumbar spine degenerative disease:a case series[J].Spinal Disord Tech,2016,29(7):371-375.
[17] CHOUDHRI T F,MUMMANENI P V,DHALL S S,et al.Guideline update for the performance of fusion procedures for degenerative disease of the lumbar spine.Part 4:radiographic assessment of fusion status[J].J Neurosurg Spine,2014,21(1):23-30.
[18] QI L,LI M,ZHANG S,et al.Comparative effectiveness of PEEK rods versus titanium alloy rods in lumbar fusion:a preliminary report[J].Acta Neurochir,2013,155(7):1187-1193.
[19] JACOBS E,ROTH A,ARTS J,et al.Reduction of intradiscal pressure by the use of polycarbonate-urethane rods as compared to titanium rods in posterior thoracolumbar spinal fixation[J].J Mater Sci:Mater Med,2017,28:148.
[20] 黄伟敏,于秀淳,梁进,等.聚醚醚酮棒椎弓根螺钉内固定系统在下腰椎退行性疾病中的应用[J].中华骨科杂志,2016,36(12):761-769.

备注/Memo

备注/Memo:
通信作者 E-mail:tanjunfeng2013@163.com(收稿日期:2019-09-01)
更新日期/Last Update: 2020-04-06